HomeGuidesAPI Reference
GuidesAPI ReferenceGitHubAirheads Developer CommunityLog In
API Reference

/system/subsystems/{type},{name}

Recent Requests
Log in to see full request history
TimeStatusUser Agent
Retrieving recent requests…
LoadingLoading…
Path Params
string
enum
required

Reference Resource: Subsystem

string
required

Reference Resource: Subsystem

Body Params
string
enum

Power supply redundancy configured for the chassis: 'none': power supply redundancy is not configured. 'n+1': N+1 power supply redundancy is configured. One power supply is redundant. 'n+n': N+N power supply redundancy is configured. The number of redundant power supplies is the same as the number of active power supplies.

Allowed:
boolean

Quick PoE configuration for this subsystem. Quick PoE provides the ability for the switch (PSE) to power up connected PDs soon after a cold reboot. This feature is applicable to subsystems of type chassis in non-modular switches, and to subsystems of type line-card in modular switches. This configuration is ignored on non-PoE capable subsystems.

string
length ≤ 64

User configurable part number for the subsystem. When this column is empty: + The subsystem is not explicitly configured yet and any compatible, supported subsystem is allowed to boot. + If an existing subsystem is physically replaced with a subsystem of a different part number, the interfaces associated with the existing subsystem will be removed prior to adding interfaces of the newly inserted subsystem. When this column is configured with a part number: + The subsystem is explicitly configured to only allow a subsystem with that specific part number to boot. + Physically replacing the existing subsystem with a subsystem of a different part number will require adjusting this column to match the new subsystem. Otherwise subsystem won't boot. + To configure the device for a new subsystem, the user can change this column with a different part number. The interfaces associated with the existing subsystem will be removed and the interfaces of the specified subsystem part number will be created.

boolean

Specify true to disable and false to enable periodic diagnostics for the respective sub system

boolean

PoE persistency configuration for this subsystem. Persistent PoE provides the ability to continue power delivery during a soft reboot of the switch. This feature is applicable to subsystems of type chassis in non-modular switches, and to subsystems of type line-card in modular switches. This configuration is ignored on a non-PoE capable subsystems.

string
enum

User configurable admin state of the subsystem. Valid values are: + diagnostic: Put the subsystem into diagnostic mode. + down: Disable/power down the subsystem. + up: Enable/power on the subsystem.

Allowed:
boolean

Specify true to disable and false to enable for the respective sub system

Responses
200

OK

204

No Content

400

Bad Request

401

Unauthorized

403

Forbidden

404

Not Found

415

Unsupported Media Type

500

Internal Server Error

501

Not Implemented

503

Service Unavailable

Language