API ReferenceNew CentralGuidesMRT APIConfiguration API
GithubAirheads Developer Community
API Reference

Update an existing gateway cluster profile configuration

List of Gateway Cluster Profiles.

Recent Requests
Log in to see full request history
TimeStatusUser Agent
Retrieving recent requests…
LoadingLoading…
Path Params
string
required
length ≤ 9999

Gateway Cluster Profile name. Manual cluster profile name should not start with auto_ prefix and it should not contain space.

Query Params
string

LOCAL - To update local objects. SHARED - To update shared objects. Default - Defaults to SHARED if not provided

string

Scope at which local object needs to be updated. Mandatory if object-type = LOCAL. Should not be provided for object-type = SHARED.

string

Device function for which the local object needs to be updated. Mandatory if object_type = LOCAL. Should not be provided for object_type = SHARED.

Body Params

profilebody object

boolean
Defaults to true

With this knob enabled, gateways will be added to the auto-cluster/removed from the auto-cluster automatically by the System. This knob should be set to false while creating the manual cluster profiles.

coa-vrrp
object

CoA-VRRP configuration

string
length between 1 and 256

User comment.

int32
500 to 65535

Gateway will wait for heartbeat threshold time (ms) before declaring a peer cluster node as dead.

ipv4-gateways
array of objects
length ≤ 2147483647

Upto 12 gateways can be configured in a profile. Based on the combination of Gateway platforms, system will restrict Gateway addition to the profile.
Ex: Presence of 70xx model gateway in the profile will reduce the Gateway count to 4.

ipv4-gateways
boolean
Defaults to false

Enable or disable the ipv6 mode in cluster profiles. ipv6-enable knob can not be toggled once the cluster profile is created.

ipv6-gateways
array of objects
length ≤ 2147483647

Upto 12 gateways can be configured in a profile. Based on the combination of Gateway platforms, system will restrict Gateway addition to the profile.
Ex: Presence of 70xx model gateway in the profile will reduce the Gateway count to 4.

ipv6-gateways
int32
1 to 4094

VLAN to be used for forwarding multicast traffic to upstream router.

string
length between 1 and 31

Gateway Cluster Profile name. Manual cluster profile name should not start with auto_ prefix and it should not contain space.

boolean
Defaults to false

Enable/disable one-to-one-redundancy mode for the cluster profile.
With this knob enabled, only 2 gateways are allowed in the cluster profile.
Leader is active and non-leader is standby.

boolean
Defaults to false
Responses

Language
Credentials
OAuth2
URL
LoadingLoading…
Response
Click Try It! to start a request and see the response here! Or choose an example:
application/json